NEURO SPRING into NEURO CLASSIC-SWING

Conversion of the System Ankle Joints

This online tutorial describes the conversion of a NEURO SPRING into a NEURO CLASSIC-SWING system ankle joint. The NEURO SPRING is a system ankle joint with dorsiflexion assist. You can convert it into a NEURO CLASSIC-SWING system ankle joint in order to have a joint with increased dorsiflexion assist and dynamic plantar flexion stop.

You will find more information about the system ankle joints in the manual of the NEURO SPRING and in the manual of the NEURO CLASSIC-SWING.

In addition, you can find the online tutorial about the joint assembly of the NEURO SWING system ankle joint here.

 

Fase 1/4

The NEURO SPRING is a system ankle joint with dorsiflexion assist which you can convert into a NEURO CLASSIC-SWING with increased dorsiflexion assist and dynamic plantar flexion stop in only a few steps.

Fase 2/4

To do so, you need the functional unit of the NEURO CLASSIC-SWING system ankle joint, consisting of:

  • the cover plate;
  • the screw unit and
  • the countersunk flat head screws.

And the set for converting to plug + go modularity, consisting of:

  • the bearing nut;
  • two feather keys with pin and
  • the outer assembly/lamination dummy.

Note: Mind the corresponding system width!

Fase 3/4

Grind the system stirrup with a round file up to the laser line.

Fase 4/4

After having ground the part marked with a line, the system stirrup looks as shown on the right picture.
Note: Make sure not to create any predetermined breaking points when grinding

Fase 1/4

Mount the system joint as described in the Joint Assembly NEURO SWING. In order to press in the feather keys with pin, please note the corresponding online tutorial. The spring unit is not mounted in this step.

Fase 2/4

Bring the system joint in plantar flexion and check if the cover plate fits well in the laminate. Adapt the laminate, if necessary.

Fase 3/4

Also check if the back of the cover plate fits well and adapt the laminate, if necessary.

Fase 4/4

Insert the spring unit as described in the Joint Assembly NEURO SWING and do not turn it in further than up to the system stirrup.
If the dorsiflexion stop has been removed, turn in the spring unit until the angle of the lower leg to the ground is correct in the shoe while holding the orthosis against the spring force.

Last Update: 11 December 2018

 


×

Tabella cookie tecnici:

Nome Scopo Durata della memorizzazione Gestore Tipo
fe_typo_user Questo cookie è un cookie di sessione standard di TYPO3; salva i dati di accesso inseriti per il login di un utente in un’area chiusa. Durata della sessione TYPO3 Association, Sihlbruggstrasse 105, 6340 Baar, Svizzera HTTP
rc::c Distingue tra esseri umani e robot Durata della sessione Google Ireland Limited, Google Building Gordon House, 4 Barrow St, Dublin, D04 E5W5, Irland HTML
×

Tabella cookie marketing:

Nome Scopo Durata della memorizzazione Gestore Tipo
_ga Registra un ID univoco per generare dati statici per l'utilizzo del sito Internet da parte dell'utente. 2 anni Google Ireland Limited, Google Building Gordon House, 4 Barrow St, Dublino, D04 E5W5, Irlanda HTTP
_gid Registra un ID univoco per generare dati statici per l'utilizzo del sito Internet da parte dell'utente. 1 giorno Google Ireland Limited, Google Building Gordon House, 4 Barrow St, Dublino, D04 E5W5, Irlanda HTTP
_gat l cookie _gat_UA contiene inoltre il numero di identificazione (_gat_ <***>) del conto di Google Analytics o del sito Internet a cui fa riferimento il cookie. 1 giorno Google Ireland Limited, Google Building Gordon House, 4 Barrow St, Dublino, D04 E5W5, Irlanda HTTP
_gcl_au È utilizzato da Google AdSense per l’efficacia pubblicitaria sui siti Internet. 3 mesi Google Ireland Limited, Google Building Gordon House, 4 Barrow St, Dublino, D04 E5W5, Irlanda HTTP
r/collect Trasmette dati mediante il dispositivo e il comportamento dell’utente su Google Analytics. Durata della sessione Google Ireland Limited, Google Building Gordon House, 4 Barrow St, Dublino, D04 E5W5, Irlanda Pixel