System Ankle Joints for Orthoses

System ankle joints can contain multiple functional elements. Functional elements have a decisive effect on the orthosis function. Depending on the intended orthosis function, different functional elements can be combined with one another.
With the Orthosis Configurator, you can easily and quickly determine the best option for the patient's system ankle joint. Based on the patient data, the Orthosis Configurator identifies the best combination of functional elements and thus guarantees an individually fitted orthosis’ alignment that ideally compensates for the patient's functional restrictions.

The orthosis functions dorsiflexion stop and plantar flexion stop have a decisive role in the orthosis' overall effect. With regard to the dorsiflexion stop, an orthosis can be equipped as follows:

  • no dorsiflexion stop
  • with static dorsiflexion stop
  • with dynamic dorsiflexion stop

Below you will find an overview of the FIOR & GENTZ system ankle joints divided according to the type of dorsiflexion stop:

System Ankle Joints with No Dorsiflexion Stop

System Ankle Joints with Static Dorsiflexion Stop

System Ankle Joints with Dynamic Dorsiflexion Stop

The following variants are available for the plantar flexion stop:

  • without plantar flexion stop
  • without plantar flexion stop, with dorsiflexion assist
  • static plantar flexion stop
  • dynamic plantar flexion stop, with dorsiflexion assist

FIOR & GENTZ system ankle joints offer adjustment possibilities in the range of motion in

  • dorsiflexion
  • plantar flexion
  • dorsiflexion and plantar flexion

plug + go Modularity due to Exchangeable Functional Units

The functional elements are integrated into the cover plates of the system joints. The functional elements by FIOR & GENTZ include, for example, precompressed spring units in various spring forces as well as system components for adjusting the ideal orthosis’ alignment. The orthosis’ alignment, the range of motion and the orthosis' rigidity can be adjusted independently as required for all important orthosis functions, such as dorsiflexion stop and plantar flexion stop.

In combination with the functional elements, the cover plates constitute the functional units of the system joints. Many FIOR & GENTZ system ankle joints can be converted from one to another. System ankle joints with plug + go modularity (identified by the plug + go logo) are especially easy to convert, as they have identical system stirrups, joint’s upper parts and assembly/lamination dummies. All functional differences are integrated in the functional unit. A joint-specific functional unit therefore is all that is needed for the conversion. Thus, by using system joints with plug + go modularity, the orthosis can be adjusted flexibly to the course of therapy and expensive new productions can be avoided.

An overview of the system joints is available for download as a PDF.


×

Tabella cookie tecnici:

Nome Scopo Durata della memorizzazione Gestore Tipo
fe_typo_user Questo cookie è un cookie di sessione standard di TYPO3; salva i dati di accesso inseriti per il login di un utente in un’area chiusa. Durata della sessione TYPO3 Association, Sihlbruggstrasse 105, 6340 Baar, Svizzera HTTP
rc::c Distingue tra esseri umani e robot Durata della sessione Google Ireland Limited, Google Building Gordon House, 4 Barrow St, Dublin, D04 E5W5, Irland HTML
×

Tabella cookie marketing:

Nome Scopo Durata della memorizzazione Gestore Tipo
_ga Registra un ID univoco per generare dati statici per l'utilizzo del sito Internet da parte dell'utente. 2 anni Google Ireland Limited, Google Building Gordon House, 4 Barrow St, Dublino, D04 E5W5, Irlanda HTTP
_gid Registra un ID univoco per generare dati statici per l'utilizzo del sito Internet da parte dell'utente. 1 giorno Google Ireland Limited, Google Building Gordon House, 4 Barrow St, Dublino, D04 E5W5, Irlanda HTTP
_gat l cookie _gat_UA contiene inoltre il numero di identificazione (_gat_ <***>) del conto di Google Analytics o del sito Internet a cui fa riferimento il cookie. 1 giorno Google Ireland Limited, Google Building Gordon House, 4 Barrow St, Dublino, D04 E5W5, Irlanda HTTP
_gcl_au È utilizzato da Google AdSense per l’efficacia pubblicitaria sui siti Internet. 3 mesi Google Ireland Limited, Google Building Gordon House, 4 Barrow St, Dublino, D04 E5W5, Irlanda HTTP
r/collect Trasmette dati mediante il dispositivo e il comportamento dell’utente su Google Analytics. Durata della sessione Google Ireland Limited, Google Building Gordon House, 4 Barrow St, Dublino, D04 E5W5, Irlanda Pixel